Do Soft Starters Generate Harmonics? A Practical Guide From a Soft Starter Supplier Soft Starter

If you’re an engineer, facility manager, or someone involved in motor control system design, you’ve likely encountered the question: do soft starters generate harmonics? As a supplier who’s walked this aisle with clients for over a decade, I’ve heard this more times than I can count—sometimes from teams who were burned by legacy equipment, sometimes from teams building new industrial lines and trying to avoid power quality headaches before they start. Let’s cut through the noise, because the answer isn’t a simple “yes” or “no”—it’s nuanced, and it depends on how the soft starter is designed, installed, and integrated into your system.
First, let’s ground this in what a soft starter does, and what harmonics are. A soft starter is a device used to gradually ramp up the voltage supplied to an electric motor during startup, rather than applying full voltage all at once. That gradual ramp reduces the inrush current—often 5-7 times the motor’s rated current for direct-on-line (DOL) starts— which saves energy, reduces mechanical stress on motors and driven equipment like pumps, conveyors, and fans, and eases strain on your facility’s electrical grid.
Harmonics, on the other hand, are distortions of the standard 50Hz or 60Hz AC sine wave that powers most industrial systems. When non-linear loads draw current in pulses rather than smoothly, they create harmonic frequencies that are integer multiples of the fundamental line frequency. For example, a 60Hz fundamental will generate 120Hz (2nd harmonic), 180Hz (3rd), 240Hz (4th), and so on. These extra frequencies can cause all sorts of problems: overheating in transformers and motors, false tripping of circuit breakers, premature wear on power factor correction capacitors, and even interference with sensitive control systems.
So where do soft starters fit in? Traditional low-voltage soft starters, the kind we supplied 15 years ago, use back-to-back silicon-controlled rectifiers (SCRs) to regulate the voltage to the motor. SCRs are semiconductor devices that turn on and off at specific points in the AC cycle to adjust the average voltage supplied. That switching is non-linear—so yes, traditional SCR-based soft starters do produce harmonics, especially during the ramp-up and ramp-down stages of operation.
But let’s get specific about how much. For a standard 3-phase SCR soft starter, the primary harmonics generated are the 5th, 7th, 11th, and 13th harmonics. Total Harmonic Distortion (THD) levels for these can range from 20% to 40% during startup, depending on the load type, the depth of the voltage cut during the initial ramp, and the quality of the SCR switching. That’s a noticeable amount—enough to raise red flags for facilities with strict power quality requirements, like food processing plants, data centers, or pharmaceutical manufacturing sites where even small harmonic distortion can disrupt production.
But here’s what many people miss: not all soft starters are created equal. Over the last 10 years, soft starter technology has evolved dramatically, and modern designs have reduced harmonic generation to levels that often fall within global power quality standards. Let’s talk about the key design choices that make a difference.
First, the number of SCRs. Early soft starters used 2 SCRs per phase, a simpler, lower-cost design. But that configuration creates more distortion because the switching pattern is less symmetrical. Modern soft starters often use 6 SCRs per phase, paired with advanced firing algorithms that adjust the timing of SCR turn-on and turn-off to produce a much smoother current waveform. The firing angle control is also more precise—instead of rough cuts, modern algorithms can ramp voltage in tiny, incremental steps that minimize the sharp current pulses that create harmonics.
Second, some soft starters now include passive or active harmonic filters integrated right into the unit. Passive filters are tuned to absorb specific harmonic frequencies (like the 5th and 7th, the most common from SCR-based drives) before they enter the grid. Active harmonic filters go a step further: they detect harmonic currents in real time and inject an opposing current to cancel them out. For these units, THD levels can drop to under 5%—well below the 5% limit set by standards like IEEE 519, which is the most widely used guideline for power quality in North America.
I’ve seen this play out firsthand with a client in the midwestern US who runs a large water treatment plant. A few years back, they were using DOL starters on their 150HP pump motors, which kept blowing fuses and causing voltage dips that disrupted their SCADA system. We installed standard SCR soft starters as a fix, but within a month, their power factor correction capacitors were failing—they traced it back to the 32% THD from the soft starters interacting with the capacitors. We swapped those for our soft starters with integrated passive filters, and within weeks, THD dropped to 4.7%, the capacitors stopped failing, and their SCADA system’s error rate went down 80%. That’s a concrete example of how the right soft starter design can turn a potential harmonic problem into a solution.
Another common misconception: harmonics from soft starters are only a problem during startup. For many old soft starter designs, that’s true—once the motor is at full speed, the SCRs are fully conducting, and the soft starter acts like a bypass contactor, so harmonic generation drops almost to zero. But wait—even modern soft starters often have a bypass function that disconnects the SCRs once the motor is at rated speed, which means most of the harmonic distortion is only present during the 10-30 seconds of startup. For facilities that run motors infrequently—like a conveyor that only starts once a day—that’s a very small window of distortion. But for facilities that run motors continuously with frequent starts—like a packaging line that restarts every few minutes—you’re looking at a lot more time with harmonic distortion. That’s where integrated filters or advanced firing algorithms make a bigger difference, because they reduce distortion even during steady-state operation if the soft starter is not bypassed.
Now, let’s address the exceptions. There are some cases where even the best soft starters will generate significant harmonics, and those are almost always related to the application or installation. For example: if you’re operating a soft starter on a weak grid (a grid with high impedance, common in remote areas or facilities with long power runs), even small levels of harmonic distortion from the soft starter can cause voltage distortion that propagates through the entire grid. Or if you’re running multiple soft starters in close proximity without proper phase balancing, their harmonic currents can add up, increasing total THD more than any single unit. I’ve also seen issues with soft starters paired with very small motors (less than 10% of the soft starter’s rated current) — the low load means the SCRs are not operating in their optimal range, leading to less precise switching and higher harmonics.
So what can you do to mitigate harmonics when using a soft starter? Let’s break down actionable steps, from our experience as a supplier:
-
Match the soft starter to your motor and load correctly. Don’t use a soft starter rated for a 200HP motor on a 15HP motor—too much capacity leads to inefficient SCR operation and higher harmonics. Our team often reviews motor data with clients before recommending a model, to make sure we pick the right size.
-
Consider your startup frequency. If your motor starts 10+ times an hour, the small harmonic window adds up fast—so invest in a soft starter with built-in harmonic reduction, not a basic model.
-
Check your grid and power quality requirements. If your facility has strict IEEE 519 compliance, or sensitive equipment like medical devices or data center servers, prioritize soft starters with THD below 5%. We recently supplied a batch of soft starters to a hospital’s HVAC system, where their sensitive MRI equipment required THD under 4%—the integrated active filters on those units delivered exactly what they needed.
-
Add a line reactor if needed. If you’re installing a basic SCR soft starter without integrated filters, a small line reactor (a simple, low-cost device that smooths current) can reduce harmonics by 10-15% without a major investment. We recommend this as a cost-effective middle ground for facilities that don’t want to upgrade to a premium soft starter.
Now, let’s put this in perspective relative to other common motor control devices. Direct-on-line starters generate almost no harmonics—because they switch the motor on directly, with no SCR switching. Variable frequency drives (VFDs), which are another common motor control device, do generate harmonics, often at similar or higher levels than basic SCR soft starters, especially when used for variable speed operation. So soft starters actually compare favorably to VFDs when it comes to harmonic generation, especially if you don’t need variable speed control—soft starters are designed only for startup and sometimes stop, not for adjusting motor speed, so their harmonic footprint is smaller than most VFDs for the same motor size.
That’s a point I always emphasize to clients who are weighing soft starters vs VFDs: if your only goal is to reduce inrush current and mechanical stress during startup, a soft starter is a better choice for power quality, because you avoid the constant harmonic generation that comes with VFDs operating at partial speed. We had a client in the automotive industry last year who replaced VFDs on their conveyor system with soft starters, and their overall THD dropped from 22% to 7%—that’s a huge improvement, all by switching the right device for their use case.
Let’s wrap this up with a reality check. Soft starters don’t have to be a major source of harmonics, but they can be, depending on the unit’s design and your application. The key is not to accept “soft starters generate harmonics” as a blanket statement, but to work with a supplier who understands the tradeoffs between cost, performance, and power quality.
If you’re currently dealing with harmonic issues from your soft starters, or you’re planning a new installation and want to avoid power quality problems before they start, we’re here to help. We’ve worked with facilities across industries—water treatment, manufacturing, healthcare, food and beverage—to match soft starter solutions to specific power quality needs, from basic applications to highly regulated environments.

If you’d like to discuss your motor control needs, ask about THD levels for our soft starter models, or get guidance on mitigating harmonic issues in your system, reach out to our team to arrange a confidential consultation.
3 Phase Voltage Protector References:
- IEEE 519-2022, Recommended Practice and Requirements for Harmonic Control in Electric Power Systems
- "Power Quality Effects of Soft Starter Harmonics in Industrial Applications", Industrial Electronics Society, 2018
- Soft Starter Design and Harmonic Mitigation, Siemens AG, 2021
- "Harmonic Distortion from SCR-Based Motor Control Devices", National Electrical Manufacturers Association (NEMA), 2020
- Active Harmonic Filters for Low-Voltage Motor Control Systems, ABB Group, 2019
Zhejiang Liuyi Electrical Technology Co., Ltd.
Zhejiang Liuyi Electrical Technology Co., Ltd. is one of the most professional soft starter manufacturers and suppliers in China. We have world-leading production equipment and strong manufacturing capabilities. Please rest assured to wholesale high quality soft starter made in China here from our factory. Customized orders are welcome.