If you’ve ever driven past an industrial storage farm at the edge of a refinery, chemical plant, or agricultural terminal, you’ve likely noticed low, broad earthen or concrete walls curving around large cylindrical tanks holding fuel, fertilizer, solvents, or other bulk materials. Those are containment berms, and if you’re working with storage tanks—whether you’re designing a new facility, retrofitting an existing site, or managing compliance for a complex—understanding exactly what they do, why they matter, and how to get them right isn’t just a nice-to-have. It’s non-negotiable for safety, regulatory compliance, and peace of mind. As a storage tank supplier that’s worked with clients across manufacturing, energy, and agribusiness for over a decade, I get asked about berms all the time: Do I need one? What size? What material? And how do I make sure it actually works when I need it? Let’s break this down in plain terms, no engineering jargon that sounds like it came out of a textbook. Storage Tank

First, let’s start with the core purpose, because that’s where most people get tripped up. A containment berm (sometimes called a secondary containment dike, bund, or retention barrier, depending on where you’re located) is a physical, engineered barrier built around or adjacent to a storage tank, designed to hold and contain all the liquid that the tank can hold if it fails. That failure doesn’t have to be a catastrophic explosion or rupture—though that’s the worst-case scenario. Most of the time, it’s something far more common: a small, unseen crack in a tank shell from corrosion, a faulty valve that leaks 500 gallons of diesel overnight, a gasket that fails during a routine fill, or even a tank being overfilled by a careless operator. Think of it like a fire extinguisher for spills: you hope you never need it, but if you do, it has to be ready.
I remember a client out in central Kansas a few years back who skipped a berm on a set of above-ground steel tanks holding anhydrous ammonia for their fertilizer distribution operation. They said the tanks were “low-pressure, so nothing bad could happen.” Until one cold winter morning, a temperature swing expanded a seam in one tank, spilling 1,200 gallons of ammonia into a drainage ditch that fed into a local creek. The state EPA fined them $120,000, they had to shut down distribution for six weeks to clean up the spill, and they lost three key accounts while they waited for permits to fix their site. When they called us a month later, the first thing they asked was what size berm they needed for all their tanks. That’s the kind of mistake a lot of small to mid-sized operations make: they see berms as an extra cost, not a critical layer of protection.
Now, let’s get into the mechanics of how a berm works, because it’s not just a wall. The biggest rule for any storage tank berm is that its total volume has to equal or exceed 110% of the largest tank it surrounds (or, if multiple tanks are grouped in a single berm, 110% of the largest tank in the group). That 10% buffer isn’t arbitrary—it accounts for any liquid that might be left in the tank’s piping, valves, or the space between the tank and the berm wall in the event of a full release. The berm also has to be built to hold that volume without failing. Earthen berms, for example, need a minimum slope (usually 3:1, meaning three feet of horizontal run for every one foot of vertical height) to prevent erosion from rain or spilled liquid, and they have to be compacted to a density that keeps them from shifting or collapsing. Concrete berms are sturdier, easier to clean after a spill, and ideal for tanks holding corrosive materials like acids or solvents, but they’re more expensive upfront. For floating roof tanks holding crude oil or other volatile products, you also have to add a leak detection sump inside the berm, so operators can spot small leaks before they turn into big spills.
A common question I get is: Can I use something other than a berm? Like a lined drainage basin or a concrete trench? The short answer is only for very small tanks holding non-hazardous materials. For most industrial storage applications, a berm is the best solution because it not only contains spills, but also prevents them from migrating off-site—something that’s required by OSHA, EPA, and most state environmental agencies. OSHA’s Process Safety Management (PSM) standard, which applies to tanks holding hazardous materials above a certain threshold, mandates secondary containment for all above-ground storage tanks, and the EPA’s Spill Prevention, Control, and Countermeasure (SPCC) rule requires berms for tanks holding oil or petroleum products. Skip that, and you’re not just risking a spill—you’re risking regulatory fines that can run into six figures, plus shutdowns, cleanup costs, and reputational damage that’s hard to recover from. I’ve had clients come to me after a friend or competitor got hit with a $500,000 EPA fine, and suddenly the $15,000 cost of a properly sized berm looks like a steal.
Let’s talk about the different types of berms, because one size definitely doesn’t fit all. Earthen berms are the most common for large storage tanks holding non-corrosive, non-hazardous liquids like diesel, gasoline, or water. They’re relatively low-cost, easy to shape around existing tank layouts, and can be planted with grass or native vegetation to reduce erosion. But they’re not ideal for areas with heavy rainfall, or for tanks holding corrosive materials, because over time, spilled chemicals can seep into the soil and weaken the berm’s structure. For those applications, concrete berms are the way to go. They’re impermeable, easy to pressure wash after a spill, and can be lined with a chemical-resistant membrane for extra protection against acids or solvents. We installed a set of concrete berms for a chemical manufacturer in Texas last year, and they told us that after a small leak from a nitric acid tank, they were able to clean it up in four hours—something that would have taken days with an earthen berm. There are also prefabricated modular berms, made from heavy-duty plastic or steel, which are great for temporary storage sites or tanks that need to be moved periodically. They’re quick to install, no excavation required, and perfect for construction sites or emergency storage operations.
One mistake I see a lot of first-time buyers make is building a berm that’s too small. I had a client in Ohio a few years back who had a 10,000-gallon diesel tank, and he built a berm that only held 8,000 gallons, figuring “it’s just diesel, not that big a deal.” When the tank’s fill valve malfunctioned one night, it poured 10,000 gallons of diesel into the berm, which overflowed and seeped into the ground beneath the tank. He ended up having to dig up 500 square feet of soil, send it off for hazardous waste disposal, and pay for a groundwater test to make sure the spill didn’t reach the local aquifer. Total cost: over $80,000, plus a year of mandatory EPA monitoring of his site. That’s why following the 110% rule is non-negotiable. It’s not a guess—it’s a regulatory requirement, and it’s a proven way to make sure your berm actually works when you need it.
Another key point: berms can’t have any gaps or openings that would allow spilled liquid to escape. That means if you have pipes running into or out of the tank, you need to build concrete or steel collars around the piping where it enters the berm, so there’s no space for liquid to leak through. You also need to have a way to drain the berm safely, without releasing any spilled liquid. A lot of operators will install a drain with a lockable valve, or a filter system that catches any contaminants before liquid is discharged. That’s not just good practice—it’s required by most environmental rules. I always advise clients to test their berms once a year, too—fill them with a known volume of water, check for leaks in the walls or floors, and make sure the drainage system works as it should. You don’t want to find out your berm has a leak when you’re dealing with a real spill.
Now, let’s get to what this means for you, as someone who works with storage tanks. If you’re planning a new tank installation, the first step is to factor the berm into your site layout from the very beginning, not as an afterthought. Measure your tank’s exact capacity, calculate the 110% volume, and work with a berm supplier that has experience matching berm materials to your tank’s contents. If you’re retrofitting an existing site with a berm, don’t just guess at the size—hire a local engineer to survey your site, take into account the terrain, rainfall, and any nearby drainage systems, to make sure the berm won’t overflow during a heavy storm. We’ve worked with clients to retrofit dozens of existing tank sites over the years, and we always do a full site assessment first, because a berm that works on flat ground in Oklahoma won’t work on sloped ground in Washington.
At the end of the day, a containment berm isn’t just a piece of equipment—it’s your first line of defense against spills, and it’s your assurance that you’re complying with regulations and protecting your site, your community, and the environment. I’ve seen too many businesses learn the hard way that skipping or cutting corners on a berm costs way more upfront than getting it right the first time. If you’re not sure what kind of berm you need, or you have questions about sizing, materials, or installation, don’t guess. Reach out to a storage tank supplier with a proven track record of safe, compliant berm installations. We work with clients of all sizes, from small farmers with a single fuel tank to large refineries with dozens of storage farms, and we can help you design a berm that fits your needs, your budget, and your regulatory requirements. Stop seeing containment berms as an extra cost—see them as an investment in protecting your business, your people, and the world around you.

If you’re ready to design or upgrade your storage tank containment system, connect with our team to discuss your specific requirements and get a customized quote tailored to your site and needs.
Distillery Equipment References
- U.S. Environmental Protection Agency. (2020). Spill Prevention, Control, and Countermeasure (SPCC) Rule. 40 CFR Parts 112.
- Occupational Safety and Health Administration. (2022). Process Safety Management of Highly Hazardous Chemicals. 29 CFR Part 1910.119.
- American Petroleum Institute. (2018). Standard for the Design and Construction of Aboveground Petroleum Storage Tanks. API 650.
- National Fire Protection Association. (2021). Standard for the Storage and Handling of Petroleum Liquids. NFPA 30.
- U.S. Environmental Protection Agency. (2019). Containment Practices for Aboveground Storage Tanks. EPA 542-F-19-003.
Hangzhou Zhengjiu Machinery Manufacturing Co., Ltd.
Hangzhou Zhengjiu Machinery Manufacturing Co., Ltd. is one of the leading storage tank manufacturers and suppliers in China. Welcome to buy discount storage tank made in China here from our factory. Quality products and low price are available.
Address: #551 Tangchuan Road, Jiangnan Town, Tonglu District, Hangzhou,China
E-mail: ashley.lee@hzzjjx.com